Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of the Korean Shoulder and Elbow Society ; : 230-235, 2017.
Article in English | WPRIM | ID: wpr-770818

ABSTRACT

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. METHODS: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. RESULTS: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. CONCLUSIONS: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.


Subject(s)
Humans , Acromioclavicular Joint , Clavicle , Follow-Up Studies , Methods , Radiography , Shoulder
2.
Clinics in Shoulder and Elbow ; : 230-235, 2017.
Article in English | WPRIM | ID: wpr-75355

ABSTRACT

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. METHODS: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. RESULTS: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. CONCLUSIONS: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.


Subject(s)
Humans , Acromioclavicular Joint , Clavicle , Follow-Up Studies , Methods , Radiography , Shoulder
3.
Malaysian Orthopaedic Journal ; : 20-23, 2011.
Article in English | WPRIM | ID: wpr-625766

ABSTRACT

We present here a technique of fracture stabilization using the Tightrope procedure in a patient with a widely displaced Neer type IIB distal clavicle fracture. The Tightrope system, typically used for stabilization of acromioclavicular joint dislocation, has not been widely described for distal clavicle fractures. The patient achieved satisfactory results after surgery; we feel that this technique is appealing as it is simple, reproducible and avoids the complications associated with extensive metalwork. This technique may also appeal to the arthroscopic surgeon.

SELECTION OF CITATIONS
SEARCH DETAIL